These Cables are designed for duct application; excellent transmission performance and protection to fibre in a variety of field environment.
|
|
Characteristics |
Values |
Reference
Standard |
| Tensile force |
1500 N |
IEC
60794-1-E1 |
| Bending radius |
20 D
|
IEC
60794-1-E11 |
| Repeated bending |
30 times, with weight of 5
Kg |
EIA-455-104 |
| Torsion resistance |
10 cycles with load of 100
N |
IEC
60794-1-E7 |
| Crush resistance |
2000 N (100 x 100 mm) |
IEC
60794-1-E3 |
| Impact resistance |
10 No, Height=0.5 mtr, Wt
- 3kg |
IEC
60794-1-E4 |
| Kink resistance |
20 D |
IEC
60794-1-E10 |
|
Temperature range
Operation
Storage
Installation |
-20º to +55ºC
-20º to +60ºC
-20º to +50ºC |
IEC
60794-1-F1 |
| Water Penetration |
Pass |
IEC 60794-1-F5 |
D = Diameter of cable in mm |
|
| Colour of fibres in a bundle |
Blue, Orange, Green, Brown,
Slate, White,
Red, Black, Yellow, Violet, Rose & Natural |
| Bundle Identification Thread |
Blue, Orange, Green, & Brown |
|
|
|
For 48 F |
|
| Cable weight (nominal) – Kg/Km |
|
90 |
|
| Cable diameter (nominal) – mm |
|
10.5 |
|
|
- Fibre in cable can comply to G651 / G652 Series / G655 or as desired. Properties of the cabled fibre available on request.
- The given cable cross section and characteristics will change as per specification desired by the customers.
|