Uni-Tube Duct Optical Fibre Cable

DESCRIPTION

These Cables are designed for duct application; excellent transmission performance and protection to fibre in a variety of field environment.

APPLICATION

Lightning prone areas

Vicinity of power line

Long Haul communication systems

Local area networks

FEATURES

All dielectric

Light weight and miniaturised

CABLE CROSS - SECTION

 

MECHANICAL & ENVIRONMENTAL CHARACTERISTICS

Characteristics

Values

Reference Standard

Tensile force 1500 N

IEC 60794-1-E1

Bending radius 20 D

IEC 60794-1-E11

Repeated bending 30 times, with weight of 5 Kg

EIA-455-104

Torsion resistance 10 cycles with load of 100 N 

IEC 60794-1-E7

Crush resistance 2000 N (100 x 100 mm)

IEC 60794-1-E3

Impact resistance 10 No, Height=0.5 mtr, Wt - 3kg

IEC 60794-1-E4

Kink resistance 20 D

IEC 60794-1-E10

Temperature range
    Operation
    Storage
    Installation


-20º to +55ºC
-20º to +60ºC
-20º to +50ºC

IEC 60794-1-F1

Water Penetration Pass IEC 60794-1-F5

D = Diameter of cable in mm

 

COLOUR CODING

Colour of fibres in a bundle Blue, Orange, Green, Brown, Slate, White,
Red, Black, Yellow, Violet, Rose & Natural
Bundle Identification Thread Blue, Orange, Green, & Brown
 

DELIVERY INFORMATION

For 48 F

 
Cable weight (nominal) – Kg/Km  
90
 
Cable diameter (nominal) – mm  
10.5
 
 

NOTES

  1. Fibre in cable can comply to G651 / G652 Series / G655 or as desired. Properties of the cabled fibre available on request.
  2. The given cable cross section and characteristics will change as per specification desired by the customers.